Vacuubrand BVC professional G Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Bombas Vacuubrand BVC professional G. VACUUBRAND BVC professional G User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - Technology for Vacuum Systems

page 1 of 68BioChem-VacuuCenterBVC controlBVC control GBVC professionalBVC professional GInstructions for useTechnology for Vacuum Systems

Página 2

page 10 of 68Safety during operation➨ Avoid interactions of the media in the collection bottle absolutely. Comply with material safety data sheets an

Página 3 - Contents

page 11 of 68➨ Adopt suitable measures to prevent the release of dan-gerous, toxic, explosive, corrosive, noxious or polluting uids, vapors and gases

Página 4 - Safety information!

page 12 of 68+ Comply with applicable regulations when disposing of chemicals. Take into consideration that chemicals may be polluted. Take adequate

Página 5

page 13 of 68Electronic equipment is never 100% fail-safe. This may lead to an indenite status of the equipment. Failure of the pumping unit (

Página 6 - Intended use

page 14 of 68➨ Never operate the pump if covers or other parts of the pump are disassembled. Ensure that the pump cannot be operated accidentally.➨ Is

Página 7

page 15 of 68TypeBVC control / GBVC professional / GPumpMaximum pumping speed(ISO 21360) at 50/60 Hzcfm(m3/h)0.4/ 0.5(0.7 / 0.85)Ultimate vacuum (abso

Página 8 - Ambient conditions

page 16 of 68We reserve the right for technical modications without prior notice!TypeBVC control / GBVC professional / GSystemVolume of collection bo

Página 9 - Operating conditions

page 17 of 68We reserve the right for technical modications without prior notice!Components Wetted materialsPumpHousing cover insert PTFE, carbon rei

Página 10 - Safety during operation

page 18 of 68Position Designation1 Pump ME 1C2 Mains connection3 Fuse holder4 On / Off switch5 Touch panel6 Rating plate7 Outlet8 Connection tubing9 H

Página 11

page 19 of 68 BVC control G617214121310119481553 BVC professional61721412131011948155316

Página 12

page 2 of 68Trademark index:VACUU•LAN® (US-Reg.No 3,704,401), VACUU•BUS®, VACUU•CONTROLTM, chemistry-HYBRIDTM, Peltronic®, TURBO•MODETM, VARIO®

Página 13 - Maintenance and repair

page 20 of 68 BVC professional G61721412131011948155316System switched offSystem switched onOn / Off switchAttention: Operate the on/off switch only

Página 14

page 21 of 68Read and comply with the document ”Safety information for vacuum equipment - Sicher-Sicher-heitshinweise für Vakuumgeräte”!1Safety

Página 15 - Technical data

page 22 of 68 Operation BVC control / BVC control GDo not press the keys. Only touch the keys of the touch panel.The keys “+“ and “-“ have to be touch

Página 16 - BVC professional / G

page 23 of 68NOTICEDepending on ambient atmospheric pressure (depending on altitude or weather conditions) and on the vapor pressure of the media insi

Página 17 - Wetted parts

page 24 of 68 Operation BVC professional / BVC professional GDo not press the keys. Only touch the keys of the touch panel.The keys “+“ and “-“ have t

Página 18 - System parts

page 25 of 68Depending on ambient atmospheric pressure (depending on altitude or weather conditions) and on the vapor pressure of the media inside the

Página 19 - BVC professional

page 26 of 68 Level sensor of BVC professional / BVC professional GThe sensor foil is located on the bottle support.The level sensor gives an alarm an

Página 20 - BVC professional G

page 27 of 68Use only the original VACUUBRAND BVC bottle or the original spare bot-tle (see “Accessories - Spare parts”).Do not x adhesive foil or so

Página 21 - Use and operation

page 28 of 68The BVC professional (with 4l polypropylene bottle) is equipped with quick couplings at the bottle head (1) and at the inlet of the

Página 22

page 29 of 68Silencer at the outletAttention: Dust-laden gases, deposits and con-densed solvent vapor can restrict air ow out the silencer. T

Página 23

page 3 of 68ContentsSafety information! ...4Important information! ...

Página 24

page 30 of 68 ShutdownShort-term:Empty bottle.Has the pump been exposed to condensate?Set the VHCpro to continuous aspiration and the BVC to max

Página 25

page 31 of 68FilterMidisart® 20000.20 µm PTFEINsartorius stedimThe hydrophobic lter retains water and aqueous solu-tions also in the form of a

Página 26

page 32 of 68Emptying the collection bottle of the BVC control and BVC control GCheck liquid level in the collection bottle regu-larly.Maximally admis

Página 27

page 33 of 68Emptying the collection bottle of the BVC professional and BVC professional GThe level sensor switches off the pump at a liquid level

Página 28 - During operation

page 34 of 68Vent the collection bottle.Remove the tubing at the inlet of the pump or disconnect coupling.Remove screw cap from the collection bottle

Página 29 - Filtration

page 35 of 68AutoclavingThe collection bottle with bottle head and screw cap, the quick coupling and the lter are des-ignated for steam sterilizatio

Página 30 - Shutdown

page 36 of 68+ Using corrosive disinfectants may result in damage, malfunction and/or failure of the equipment.+ Chlorine permeates the hydropho

Página 31

page 37 of 68Sekusept® PlusThe use of the disinfectant Sekusept® Plus (Manufacturer: Ecolab GmbH & Co OHG, Düs-seldorf, Germany) in ext

Página 32 - BVC control G

page 38 of 68At the factory, the level sensor is adjusted either to the 4l polypropylene bottle or to the coated 2l glass bottle (G version) at standa

Página 33 - Disinfection routine

page 39 of 68NOTICEDo not attach adhesive foil or anything similar to level sensor or to the side of the bottle directly next to the sensor.adhesive f

Página 34

page 4 of 68Safety information!Important information!+ Keep this manual complete and accessible to per-sonnel at all times!+ Read this manual carefull

Página 35 - Cleaning and decontaminating

page 40 of 68Adjustment routine for BVC professional with 4l polypropylene bot-tle from software version V1.6, see rating plateAction Reaction Meaning

Página 36 - Chlorine

page 41 of 68Adjustment routine for BVC professional with 2l glass bottle from software version V1.6, see rating plateAction Reaction MeaningStep 1Tou

Página 37 - Sekusept

page 42 of 68Assembling of componentsAttach new lter.Observe ow direction. Position lter with the printed side “IN” towards the bottle.Attach

Página 38 - Preparation

page 43 of 68 Assembling a second VHCpro connection set (with / without coupling) or conversion to quick coupling VHCpro - bottle)Empty bottle.De

Página 39

page 44 of 68BVC with polypropylene bottleInsert hose connection (1a) with seal ring (2) or coupling (1b) with seal ring (2) in the screw cap.Secure

Página 40

page 45 of 681234 Assembling quick coupling bottle - pump unit (extension set)Remove tubing.Disassemble hose nozzle.Hold counter piece with open-

Página 41

page 46 of 68 Assembling a hose nozzle at the bottle head of the BVCEmpty bottle.Decontaminate equipment if necessary.Remove lter with connection tub

Página 42 - Assembling of components

page 47 of 68Quick coupling set: VHCpro to bottleQuick coupling made of PVDF, with adapter to connect a VHCpro to a collection bottle. When disconnect

Página 43 - - bottle)

page 48 of 68Collection bottle 4L, made of PP, with protection lter and inlet tube ...635810Collection bottle 2L glass, coated,with pr

Página 44

page 49 of 68Protection lter with connection hoses ...638266Silicone hose 12/6 mm (length in cm) ... 635741 VacuuHandControl VHCpro ...

Página 45 - (extension set)

page 5 of 68➨ DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. + WARNING indicates a hazardous si

Página 46

page 50 of 68Fault Possible cause Remedy❑ Pump fails to start, system becomes vented.➨Not plugged in, or failure of electrical supply?✔Plug in, or che

Página 47 - Quick coupling sets

page 51 of 68Fault Possible cause Remedy❑Pump is running continuously.➨Leak in the system?✔Check tubing, seals, coupling, and blind cap. Screw in or r

Página 48 - Accessories - spare parts

page 52 of 68➨ Never operate the pump if covers or other parts of the pump are disassembled. ➨ Before starting maintenance, disconnect the electri-cal

Página 49

page 53 of 68Tools (metric):- Diaphragm key SW 46 (included in the set of seals)- Screw driver Torx TX20- Open-ended wrench SW 19Set of seals BVC

Página 50 - Troubleshooting

page 54 of 68➨ Unscrew hose nozzle, or hose nozzle with coupling, using an open-ended wrench.➨ Unscrew elbow tting with silencer at the o

Página 51 - Fault Possible cause Remedy

page 55 of 68View of the disassembled pump head parts ME 1C1: Cover of housing cover2: Housing cover3: Housing cover insert4: Valves5: Head cove

Página 52

page 56 of 68➨ Lift diaphragm carefully sidewise.+ Never use a pointed or sharp-edged tool to lift the diaphragm.➨ Use the diaphragm key to grip the d

Página 53

page 57 of 68+ If the old diaphragm is difcult to separate from the diaphragm support disc, immerse assembly in naphtha or petroleum ethe

Página 54

page 58 of 68➨ Position any washers that are present be-tween diaphragm support disc and connec-tion rod.➨ Screw diaphragm clamping disc, diaphr

Página 55

page 59 of 68➨ Put on housing cover and housing cover in-Put on housing cover and housing cover in-sert.+ Move housing cover insert slightly to ensure

Página 56 - Replacing the diaphragm

page 6 of 68General information+ Read and comply with this manual before installing or operating the equipment.+ Before operating the equipment read

Página 57

page 60 of 68➨ Position bottle in the support.➨ Depending on BVC version, position tubing to hose nozzle or quick coupling.Checking the ultimate vacuu

Página 58 - Assembling the pump head

page 61 of 68fuse holder➨ Keep the snap-t squeezed and pull the fuse holder out.➨ The fuse holder contains two fuses of the same type. Replace the de

Página 59

page 62 of 68Notes on return to the factoryRepair - return - DAkkS calibrationSafety and health of our staff, laws and regulations re-gardin

Página 60 - Checking the ultimate vacuum

page 63 of 68We submit repair quotations only on request and always at the customer’s expense. If an order is placed, the costs incurred for problem

Página 61 - Replacing the fuse

page 64 of 68Scrapping and waste disposal:Dispose of the equipment and any components removed from it safely in accordance with all local and

Página 62

page 65 of 68Health and safety clearance formHealth and safety clearance form for BVC systems and accessories1. Device (Model): ...

Página 63

page 66 of 68 Description of the decontamination method: Outside: ...

Página 64

page 67 of 68Hersteller / Manufacturer / Fabricant: VACUUBRAND GMBH + CO KG · Alfred-Zippe-Str. 4 · 97877 Wertheim · GermanyHiermit erklärt der Herste

Página 65

page 68 of 68Disclaimer: Our technical literature is only intended to inform our cus-tomer. The applicability of general empirical values an

Página 66 - ☐ yes ☐ no

page 7 of 68Ensure that the equipment and all components are suit-able for the intended application. Use the system only for aspiration of liquids and

Página 67

page 8 of 68Provide a rm level platform for the equipment. Ensure a stable position of the pump without any mechanical con-tact except of the pump fe

Página 68

page 9 of 68Operating conditions➨ The devices have no approval for operation in or for pumping of potentially explosive atmospheres.➨ The devices are

Comentários a estes Manuais

Sem comentários