Vacuubrand CVC 3000 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Equipamento Vacuubrand CVC 3000. VACUUBRAND CVC 3000 User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
page 1 of 80
Vacuum controller
Instructions for use
Technology for Vacuum Systems
CVC 3000
Vista de página 0
1 2 3 4 5 6 ... 79 80

Resumo do Conteúdo

Página 1 - Technology for Vacuum Systems

page 1 of 80Vacuum controllerInstructions for useTechnology for Vacuum SystemsCVC 3000

Página 2

page 10 of 80Readjustment ... 52Gauge head VSP 3000 (accessory) ...

Página 3 - page 3 of 80

page 11 of 80Safety information!Important information!+ Keep this manual complete and accessible to per-sonnel at all times!+ Read this manual carefu

Página 4

page 12 of 80➨ DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. + WARNING indicates a hazardous s

Página 5 - page 5 of 80

page 13 of 80General informationRemove all packing material from the packing box. Re-move the product from its packing-box and retain all pack-aging

Página 6

page 14 of 80+40°C), or for short periods up to +176°F (+80°C) at the pressure transducer (gas temperature). Periodical-ly check maximum temperatures

Página 7 - page 7 of 80

page 15 of 80match in voltage, phase, and frequency.• When working with residues, aggressive or condens-able media, install a gas washing bottle if

Página 8 - Reset / Language selection

page 16 of 80• Do not operate this product near ames.To the best of our knowledge the equipment is in com-pliance with the requirements of the appl

Página 9 - Contents

page 17 of 80Safety during operation➨ Adopt suitable measures to prevent the release of dangerous, toxic, explosive, corrosive, noxious or pol-luting

Página 10

page 18 of 80Maintenance and repair➨ Switch off the controller. Disconnect the power supply and wait ve seconds before starting mainte-nance to allow

Página 11 - Safety information!

page 19 of 80 ` Important information: Equipment marking (ATEX)VACUUBRAND equipment bearing mark (see rating plate)` II 3G IIC T3 X Internal Atm. onl

Página 12

page 2 of 80After sales service: Contact your local dealer or call +49 9342 808-5500Dear customer,Your VACUUBRAND controllers are designed to provide

Página 13 - Intended use

page 20 of 80The pumps are marked with ”X” (according to EN 13463-1), i.e., restric-tions of the operation conditions:• The equipment is designated f

Página 14

page 21 of 80Technical data Technical data of controllerController CVC 3000Pressure transducerceramic diaphragm (alumina), capacitive, absolute press

Página 15 - Ambient conditions

page 22 of 80We reserve the right for technical modication without prior notice!* The actual vacuum control range in your application might be reduc

Página 16 - Operating conditions

page 23 of 80 Wetted partsComponents Wetted materialsSensor Aluminum oxide ceramicVacuum connection / hose nozzle PPSensor housing PPS / glass berSe

Página 17 - Safety during operation

page 24 of 80Use and operationThe CVC 3000 VACUUBRAND controller with internal pressure transduc-er and integrated venting valve can only be operated

Página 18 - Maintenance and repair

page 25 of 80Connection plug of the power supply or of the VACUU • BUS line to NT VARIO / VARIO-B pumpjacks for connection of VACUU•BUS components

Página 19 - page 19 of 80

page 26 of 80Selection knob• Press to reach the set-up menu of the function• Turn to choose the parameter you want to modify• Press to select th

Página 20

page 27 of 80+ Maximum permissible pressure: 21.8 psi (1.5 bar) ab-solute. Attention: At pressures above approximately 795 Torr (1060 mbar) the pre

Página 21 - Technical data

page 28 of 80Pump down / Vac control / Auto mode (only with NT VARIO pump) / Program / VACUULAN / CongurationSelected function (displayed in the uppe

Página 22 - Power supply (wall plug)*

page 29 of 80Control is runningWarning notice (if necessary in combination with other sym-bols), ashingCoolant valve switched onVenting valve switch

Página 23 - Abbreviations

page 3 of 80DEAchtung: Die vorliegende Betriebsanleitung ist nicht in allen EU-Sprachen verfügbar. Der Anwender darf die beschriebenen Geräte nur dan

Página 24 - Use and operation

page 30 of 80The CVC 3000 controller can be adapted to the specic application by choosing the appropriate function depending on the connected compo-n

Página 25 - Rear side CVC 3000

page 31 of 80”Vac control” • With pressure preselection, switches a pump or an in-line valve to maintain that pressure in two-point contro

Página 26

page 32 of 801013 . 2mbarVACUULAN 1013 . 2mbarPump down Pump down Speed HIMinimum OffDelay OffDuration Of

Página 27 - page 27 of 80

page 33 of 801013 . 2mbarProgram 1013 . 2mbarVac control Vac control Set vacuum 75 TorrSpeed HIMaximum OffDelay Of

Página 28 - 1013 . 2

page 34 of 80Pump down function➨ Continuous pumping with pressure and time settings• Operation of a vacuum pump via in-line valve• Operation of a v

Página 29 - page 29 of 80

page 35 of 80The screen-shot shows the factory-set values.When selecting ”Graphic” the display shows a pressure vs. time curve.The timeline in the di

Página 30

page 36 of 80Vac Control function➨ Vacuum control to a preset vacuum value• Operation of a vacuum pump via in-line valve• Operation of a vacuum pu

Página 31 - page 31 of 80

page 37 of 80+ Speed (only for NT VARIO / VARIO-B pumps): The maximum motor speed can be preselected (to control the pumping speed). The ”Speed” i

Página 32 - Menu guide

page 38 of 80The screen-shots show the factory-set values.Vac control Set vacuum 75 TorrSpeed HIMaximum OffDelay

Página 33

page 39 of 80Auto mode (only NT VARIO / VARIO-B pumps)Preselections+ Use the selection knob to set the parameters. + Sensitivity: The ”Sensitivity”

Página 34 - Pump down function

page 4 of 80DA Bemærk: Denne manual foreligger ikke på alle EU sprog. Brugeren må ikke be-tjene apparatet hvis manualen ikke er forstået. I det tilfæl

Página 35 - Pump down

page 40 of 80+ Duration: ”Duration” determines the total process time since control start. The ”Duration” is adjustable between 1-1440 minutes (24 h

Página 36 - Vac Control function

page 41 of 80Program function➨ Permits ten programs to be dened and stored, each with up to ten program steps with preset values for vacuum and tim

Página 37 - Vac control

page 42 of 80The screen-shot shows the factory-set values.Editing:+ To select row: turn and press selection knob.+ To adjust parameter: turn the sel

Página 38 - 760 Torr

page 43 of 80Example 1 NT VARIO vacuum pump with speed control (e.g., with a rotary evap-orator): Degassing and automatic distillation with timing Pr

Página 39 - page 39 of 80

page 44 of 80Program step 1 should be always a denite initial state, here atmospheric pressure (ATM). To reach this state denitely, set a tickmark

Página 40 - Auto mode

page 45 of 80In step 2, pumping down begins, reaching 10 Torr/mbar within 5 minutes (linear ramp), as ”Step” is not set. Step 3: Vacuum holds there f

Página 41 - Program function

page 46 of 80This screen-shot shows the factory-set values.VACUULAN 40 mbar00:13:00VACUULAN Set vacuum 19 TorrSwitch on

Página 42 - Program 5 : 4 1013mbar

page 47 of 80Assembly of a vacuum system+ Assemble vacuum connection lines between CVC 3000 controller or an external pressure transducer, vacuum pu

Página 43 - Application example

page 48 of 80+ Select ”Pump down” function. ”Speed” (only with NT VARIO / VARIO-B pumps) ”HI” is recommended. For gel dryers set a lower speed if nec

Página 44

page 49 of 80alternatively:For diaphragm pump with in-line valve and/or Vacuum-Management-System+ Select ”Vac control” function.+ Set ”Set vacuum”

Página 45 - VACUULAN function

page 5 of 80HUFigyelem! Ez a kezelési utasítás nem áll rendelkezésre az EU összes nyelvén. Ha a felhasználó nem érti jelen használati utas

Página 46 - 00:13:00

page 50 of 80alternatively:Fully automatic determination and adaptation of the boiling point with NT VARIO / VARIO-B diaphragm pumps (recommended)+ Se

Página 47 - Application examples

page 51 of 80CongurationIn the ”Conguration” menu the device parameters are preselected. After 20 seconds without action the function ”Conguration

Página 48 - (e.g., rotary evaporator)

page 52 of 80This screen-shot shows the factory-set values.+ Autostart: If ”Autostart” is set to ”On” the controller restarts a running process autom

Página 49 - page 49 of 80

page 53 of 80Adjustment at atmospheric pressureAn adjustment at atmospheric pressure is only possible if the pressure is higher than 525 Torr (700 mb

Página 50

page 54 of 80Adjustment at a reference pressureInstead of adjustment under vacuum to a pres-sure < 0.1 Torr (mbar), adjustment to a precise-ly know

Página 51 - Conguration

page 55 of 80Note: The active pressure transducer (VSP 3000) is not displayed in the sta-tus line of the controller display!When operating the CVC 30

Página 52 - Readjustment

page 56 of 80The vacuum gauge head VSP 3000 was adjusted using factory standards, which are traceable through regular calibration in an accredited lab

Página 53 - Adjustment under vacuum

page 57 of 80Adjustment under vacuumAn adjustment under vacuum is only possible in the lower pressure range.➨ Evacuate the measurement connection of

Página 54 - 0...15 Torr

page 58 of 80Manual switching between pressure transducers➨ Select the menu item ”Sensors” in the menu ”Conguration”.+ Connected gauge heads are disp

Página 55 - page 55 of 80

page 59 of 80+ This requires the external gauge head to be dened as reference (VACUU•BUS address ”Ref. 1”) and no gauge head VSK 1 to be c

Página 56 - 750 Torr

page 6 of 80NL Attentie: Deze gebruiksaanwijzing is niet in alle talen van de EU verkrijgbaar. De gebruiker moet niet met dit apparaat gaan werken als

Página 57

page 60 of 80Calibration in the factoryTo order DAkkS calibration of the CVC 3000 pressure transducer, order number: ...

Página 58

page 61 of 80Interface parametersThe CVC 3000 controller is equipped with a serial interface (RS 232C, nine-pin Sub-D-plug).+ Plug-in or remove the c

Página 59 - Reconguring the gauge head

page 62 of 80Command Operation Response DescriptionIN_PV_1 current pressureXXXX mbar/Torr/hPaunit according to preselectionsIN_PV_2 current frequency

Página 60 - Calibration in the factory

page 63 of 80 Write commands ”CVC 2000”Command Operation Parameter DescriptionOUT_MODE function123 30 31 32continuous pumpingvacuum control without a

Página 61 - Interface parameters

page 64 of 80** If remote operation is selected or deselected, the user has to ensure that no dangerous status of the system can occur due to the cha

Página 62 - Pin assignment RS-232 C

page 65 of 80 Read commands ”CVC 3000”Command Operation Response DescriptionIN_PV_1 current pressure XXXX.X mbar/Torr/hPa unit according to preselect

Página 63 - Write commands ”CVC 2000”

page 66 of 80Command Operation Response DescriptionIN_STATstatus process control0XXXXX1XXXXXX0XXXXX1XXXXXX0XXXXX1XXXXXX0XXXXX1XXXXXX0XXXXX1XXXXX2XXXXX

Página 64

page 67 of 80 Write commands ”CVC 3000”Attention (OUT_MODE): If control is running, it is only possible to switch either from 1 to 2, or from 2 to 3,

Página 65 - Read commands ”CVC 3000”

page 68 of 80Command Operation Parameter DescriptionOUT-SP_1 set vacuum XXXXunit according to preselection; see re-spective function for parameter ran

Página 66

page 69 of 80* If remote operation is selected or deselected, the user has to ensure that no dangerous status of the system can occur due to the ch

Página 67 - Write commands ”CVC 3000”

page 7 of 80SEVarning: Denna instruktion är inte tillgänglig på alla språk inom EU. Användaren får inte starta utrustningen om hon/han inte förstår d

Página 68

page 70 of 80Use VACUU•BUS Y-adapters and extension cables to connect further components. When connecting an external pressure transducer, it

Página 69 - Accessories

page 71 of 80Fault Possible cause Remedy❑ No display.➨Power supply not plugged in (wall plug)?✔Plug in power supply.➨CVC 3000 controller switched of

Página 70

page 72 of 80Fault Possible cause Remedy❑ Warning triangle and black valve symbol are ash-ing, two blips*.➨External venting valve removed or defectiv

Página 71 - Troubleshooting

page 73 of 80* only if ”Sound” ”On” is selected** VMS: Vacuum management system to switch non-VARIO pumps Fault Possible cause Remedy❑”Vac contro

Página 72 - Fault Possible cause Remedy

page 74 of 80Notes on return to the factoryRepair - return - DAkkS calibrationSafety and health of our staff, laws and regulations re-garding the han

Página 73 - page 73 of 80

page 75 of 80We submit repair quotations only on request and always at the customer’s expense. If an order is placed, the costs incurred for problem

Página 74

page 76 of 80Scrapping and waste disposal:Dispose of the equipment and any components removed from it safely in accordance with all local and national

Página 75 - page 75 of 80

page 77 of 80Health and safety clearance form1. Device (Model): ... 2. Serial no.:

Página 76 - Warranty

page 78 of 80Hersteller / Manufacturer / Fabricant: VACUUBRAND GMBH + CO KG · Alfred-Zippe-Str. 4 · 97877 Wertheim · GermanyHiermit erklärt der Herste

Página 77

page 79 of 80This certicate is only valid for pumps with the respective mark (Li-censed Test mark) on the pump rating plate.

Página 78

page 8 of 80PortuguêΡyccкийPolskiNederl.Suomi日本語中文 한국어CVC 3000 V2.0DeutschEnglishFrançaisItalianoEspañolTürkçeReset / Language selection1

Página 79 - page 79 of 80

page 80 of 80Disclaimer: Our technical literature is only intended to inform our cus-tomer. The applicability of general empirical values and results

Página 80

page 9 of 80ContentsReset / Language selection ............ 8Safety information! .........

Comentários a estes Manuais

Sem comentários